Dual-Channel Temperature Monitors and
Fan-Speed Controllers with Thermistor Inputs
______________________________________________________________________________________ 13
Table 3. Register Map (continued)
R/W ADD
POR
STATE
FUNCTION
D7
D6
D5
D4
D3
D2
D1
D0
R
0Dh
0000
000x
PWM1
instantan-
eous duty
cycle
MSB
(128/240)
LSB
(2/240)
R
0Eh
0000
000x
PWM2
instantan-
eous duty
cycle
MSB
(128/240)
LSB
(2/240)
R/W 0Fh
0000
0000
Channel 1
fan-start
temperature
MSB
LSB
R/W 10h
0000
0000
Channel 2
fan-start
temperature
MSB
LSB
R/W 11h
0000
000x
Fan
configuration
Hysteresis:
0 = 5癈, 1
= 10癈
Temp
step : 0 =
1癈,
Fan 1:
control 1
= Ch 1
Fan 1:
control 1
= Ch 2
Fan 2:
control 1
= Ch 1
Fan 2:
control 1
= Ch 2
R/W 12h
1011
01xx
Duty-cycle
rate of
change
Fan 1 MSB
Fan 1
LSB
Fan 2
MSB
Fan 2
LSB
R/W 13h
0101
0101
Duty-cycle
step size
Fan 1 MSB
Fan 1
LSB
Fan 2
MSB
Fan 2
LSB
R/W 14h
010x
xxxx
PWM
frequency
select
Select A
Select B Select C
R/W 15h
xx00
000*
GPIO
function
GPIO5:
0 =
output; 1
= input
GPIO4:
0 =
output; 1
= input
GPIO3:
0 =
output; 1
= input
GPIO2:
0 =
output; 1
= input
GPIO1:
0 =
output; 1
= input
GPIO0:
0 =
output; 1
= input
R/W 16h
xx11
111*
( N ote 1)
GPIO value
GPIO5
GPIO4
GPIO3
GPIO2
GPIO1
GPIO0
R/W 17h
0000
0000
Thermistor
offset
register
Th1 MSB
(sign)
Th1 LSB
(2癈)
Th2 MSB
(sign)
Th2 LSB
(2癈)
R
18h
1111
1111
Tach1 value
register
R
19h
1111
1111
Tach2 value
register
R/W 1Ah
1111
1111
Tach1 limit
register
R/W 1Bh
1111
1111
Tach2 limit
register